1 / 3
| Model | HYZD-20 | HYZD-50 | HYZD-100 | HYZD-200 | HYZD-500 | HYZD-1000 | |
| Max. load per side(kg) | 20 | 50 | 100 | 200 | 500 | 1000 | |
| Acceleration(m/s²) | 30-1000 | 30-1000 | 30-1000 | 30-2000 | 30-500 | 30-500 | 30-500 |
| Max. dimensions of test sample (mm) | 200x200x200 | 300x300x200 | 450x450x400 | 700x700x700 | 1000x1000x1000 | ||
| Calculation radius (mm) | 600 | 750 | 7500 | 2500 | 3000 | 3500 | |
| Start-up time(mins) | ≤5 | ≤8 | ≤10 | ||||
| Continuous working time(mins) | 60 | 30 | |||||
| Power supply & consumption | AC380V 10KVA | AC380V 40KVA | AC380V 40KVA | AC380V 55KVA | AC380V 120KVA | AC380V 250KVA | |
| Power connection device | 30 rings 500V 5A | ||||||
| Overall dimensions (mm) | 1800X1500X1200 | Ф2500X1400 | Ф4000x1400 | Ф6000X1600 | Ф7000X1600 | Ф8000X1800 | |
| Control cabinet dimensions (mm) | 850X1000X1300 (Inverter cabinet 100kg or less: 600X600X1800, more than 100kg: 1200X600X2100) | ||||||
| Weight(kg) | 800 | 2800 | 3000 | 3500 | 6000 | 8000 | 10000 |
| Control system | Industrial computer control | ||||||
| Satisfy requirements | MIL-STD-202F, MIL-STD-810F, MIL-STD-883C, IEC68-2-27, GJB150, GJB360, GJB548, GB/T423 | ||||||
| Remarks | The power connection device can be configured according to user requirements; arm size can be customized; foundation maps provided separately. | ||||||