OEM VOC/aldehyde and ketone test environment chamber for automotive interior parts (sampling bag method) Manufacturer, Factories

The automotive interior VOC environmental test chamber (bag method) meets the needs of VOC emission testing of automotive parts and automotive decorative materials.

Product Description

Product Description
The equipment is mainly used to simulate different conditions of ambient temperature, humidity and air replacement rate, and place automotive interior materials or products in the test cabin to test the performance of automotive interior parts under certain conditions of temperature, humidity, and air exchange rate. VOC and aldehydes and ketones are released, and the VOC emissions of vehicle parts are tested under different conditions, so as to control the toxic and harmful gas emissions caused by the parts.
During the testing process, real-time monitoring of the background concentration of formaldehyde, toluene, and total VOC is required. Under stable conditions where the concentration reaches the limit, sampling and testing are performed to ensure the representativeness and validity of the test data.
Meet the Standards
● GB/T 27630-2011 Guidelines for the Best Evaluation of Air Quality in Passenger Cars
● GB/T31107-2014 General Technical Requirements for Climate Chambers for Testing Volatile Organic Compounds in Furniture
● HU/7400 200 Methods for the formulation of sampling of volatile organic compounds and aldehydes and ketones in vehicles
● JAMA Japan Automobile Manufacturers Association Voc Detection Method in Automobiles
● 10122192 1-2012 Interior Air of Road Vehicles-Part 1: Whole Vehicle Test-Specifications and Methods for the Determination of Volatile Organic Compounds in Cars
● WPV3938 Overall Radiation Conditions of Automobiles Gases in the Interior Space of Automobiles
● T/0IIF13-2016 Regulations for the Evaluation of the Odor of the Air in Automobiles
● VDA276 Automotive Standard
● PV3942 Popular Standard
● BMW_GS_97014-3 BMW Standard
Technical Parameters
Model HYVD-48 HYVD-24
Internal volume (m³) 48 24
Internal dimension (mm) W 6000 3000
D 4000 4000
H 2000 2000
Performance Temperature Range 15℃~85℃
Volatility ≤±0.5℃
Deviation ≤±2℃
Background value (mg/m³) Formaldehyde: ≤0.02mg/m³; Acetaldehyde: ≤0.01mg/m³, Toluene: ≤0.02mg/m³, Ethylbenzene: ≤0.02mg/m³; Xylene ≤0.02mg/m³; Styrene ≤0.002mg/m³; TVOC≤300μg/m³, single VOC≤20μg/m³.
Relative positive pressure 10±5Pa
Air velocity 0.1~1.0m/s (continuously adjustable)
Air exchange volume measurement Electronic flowmeter
Temperature control method Electric heating, SCR load regulation module, forced hot air circulation
Material (Inner Chamber) SUS304 mirror stainless steel 1.2mm
Power supply AC380V (1±10%) V 50Hz Three-phase five-wire
Noise (dB) ≤65dB
Product Display
Video Demonstration
Frequently Asked Questions
What is the primary function of this VOC test chamber?
It is designed to simulate ambient temperature, humidity, and air replacement rates to test the emission of VOCs, aldehydes, and ketones from automotive interior materials.
What temperature range can the equipment handle?
The temperature range is from 15℃ to 85℃, with a volatility of ≤±0.5℃ and a deviation of ≤±2℃.
What materials are used for the inner chamber construction?
The inner chamber is constructed from SUS304 mirror stainless steel (1.2mm thickness) to ensure testing accuracy and durability.
Does the system provide real-time monitoring?
Yes, the system requires real-time monitoring of formaldehyde, toluene, and total VOC background concentrations during the testing process.
Which international standards does this chamber comply with?
The equipment meets multiple standards including GB/T 27630, JAMA, ISO 12219, VDA276, PV3942, and BMW_GS_97014-3.
What are the available volume sizes for the test chamber?
We offer two primary models: the HYVD-48 with a 48m³ internal volume and the HYVD-24 with a 24m³ internal volume.