High-Quality 10/20/30 cubic aerosol chamber Factories, Factory

Bacterial aerosol cabinets are mainly used to evaluate the antibacterial and sterilization capabilities of products with antibacterial properties against microorganisms (bacteria) in the air.

Product Description

i

Product Description

This aerosol chamber is designed for use with fresh air purifiers that have an internal circulation and disinfection function. It has been tested and meets the T/CAQI 180-2021 Technical Requirements and Test Methods for Fresh. The aerosol chamber for disinfection function of the fresh air purifier is applicable to fresh air purifiers with internal circulation and disinfection functions. This aerosol chamber meets the test standard of "T/CAQI 180-2021 Technical Requirements and Test Methods for Fresh Air Purifier with Disinfection Function".

Meet the Standards

  • 2002 Edition Disinfection Technical Specifications
  • GB 28235-2020 Sanitary Requirements for Ultraviolet Sterilizers
  • GB 27948-2020 General Requirements for Air Disinfectants
  • GBT 38504-2020 Method for Evaluation of Spray Disinfection Effect

Technical Parameters

Chamber Type Dimensions & Application
30 cubic aerosol chamber Internal dimensions: 3400x3500x2500mm (WxDxH)
Application range: Test and evaluate the antibacterial and antibacterial performance of household appliances such as air purifiers and air conditioners.
Standard: GB 21551.3-2010 Special requirements for air purifiers.
20 cubic aerosol chamber Internal dimensions: 2800x2850x2500mm (WxDxH)
Application range: The disinfection effects of ozone sterilizers, ultraviolet sterilizers, air disinfectants, fungicides, etc.
Standard: Disinfection Technical Specification 2002 Edition, GBT38504-2020, GB27948-2020, GB 28235-2020, GB 28232-2020.
10 cubic aerosol chamber Internal dimensions: 2000x2000x2500mm (WxDxH)
Application range: Disinfection effects of ozone/ultraviolet sterilizers and air disinfectants; simulates field tests.
Standard: Disinfection Technical Specification 2002 Edition, GBT38504-2020, GB27948-2020, GB 28232-2020.
Structure requirements: Adopts a pair of adjacent aerosol chambers (2 sets). Environment factors (temperature, humidity, cleanliness, light, airtightness, ventilation) must remain consistent and stable. One for disinfection test and one for control test.
📷

Product Details Gallery

Aerosol chamber detail 1
Aerosol chamber detail 2
Aerosol chamber detail 3
Aerosol chamber detail 4
Aerosol chamber detail 5
Aerosol chamber detail 6
Aerosol chamber detail 7
Aerosol chamber detail 8

Product Video

?

Frequently Asked Questions

What is the primary application of these aerosol chambers?
They are designed to test and evaluate the antibacterial and sterilization performance of air purifiers, air conditioners, ozone sterilizers, and ultraviolet sterilizers.
What sizes are available for the test chambers?
We offer three standard internal volumes: 10 cubic meters, 20 cubic meters, and 30 cubic meters, each catering to different testing standards and equipment sizes.
Does the equipment comply with international standards?
Yes, the chambers meet multiple standards including T/CAQI 180-2021, GB 28235-2020, GB 27948-2020, and the Disinfection Technical Specification (2002 Edition).
Why are two chambers mentioned in the technical requirements?
Standard testing requires a pair of identical chambers: one for the actual disinfection test and one as a control group to ensure the accuracy and stability of the results.
What environmental conditions are maintained inside the chamber?
The system ensures stable temperature, humidity, light, airtightness, and ventilation conditions throughout the duration of the experiment.
Can it be used for air disinfectant testing?
Absolutely. The 10 and 20 cubic chambers are specifically optimized for testing the efficacy of air disinfectants and fungicides through simulated field tests.

Related Products