The temperature ventilation and cooling system of the test chamber is automatically controlled by the high-precision temperature controller.
Equipped with a water pump, time relay, and nozzle; the spraying cycle is fully adjustable to simulate various environmental conditions.
Features wireless transmission for the control blackboard thermometer, significantly improving measurement and control accuracy.
Uses optical fiber transmission to measure xenon lamp radiation intensity, eliminating measurement errors caused by temperature fluctuations.
| Model | HY-120 (Hub type) | HY-125 (Flat type) |
| Internal size (WxHxD) cm | 95x95x85 | 60x60x80 |
| Temp range | RT+10℃ ~ 90℃ | |
| Humid range | 30 ~98%RH (dark) / 20%~60%RH (light) | |
| Temp and Humid deviation | Temperature ±2°C, humidity ±3%RH | |
| Rainfall time | 0~9999 hours 59 minutes adjustable | |
| Rainfall cycle | 0~240 minutes, interval (break) adjustable | |
| Wavelength range | 280nm~800nm | |
| Xenon lamp power | 1.8/3/6KW (Lifespan: 1000 hours) | |
| Irradiation intensity | 0.30-0.57W/m² (at 340nm), 0.66-1.22W/m² (at 420mm), 35-70W/m² (at 300-400nm) | |
| Exposure area | 2200-6400m² | 3760-7500m² |
| Cooling method | Water cooling | Air cooling |
| Blackboard temperature | 63-100℃ ±3℃ | |
| Light intensity | 500w/m² - 1200w/m² | |
| Resolution accuracy | Temperature 0.01℃, humidity 0.1%RH | |